22. Measurement of Polarity in Band-Limited Systems
AES Convention: 91 Paper Number:3168
Publication Date: 1991-10-06
Polarity is usually measured by energizing the system under test with a wide-band asymmetrical test stimulus, such as a raised cosine pulse, and then observing the system`s output on an oscillioscope. For a well-behaved flat-response minimum-phase system, such as an electronic device, the polarity determination is straightforward. However, for a general band-limited non-minimum-phase system with non-flat frequency response, such as a loudspeaker, the policy assessment can be quite difficult due to waveform distortion. A measurement method is presented that uses a narrow-band asymmetrical Hann-windowed tone burst, along with synchronous detection, to evaluate polarity at many points across a desired bandwidth. For a general system evaluated with tone bursts over a narrow frequency range, polarity is not just a simple two-valued function, but a continuum of values over the range of +/- 180 degrees, that varies with frequency. A preliminary theory is presented that allows prediction of the tone-burst phase, and hence time-constrained narrow-band polarity (herein called polarity phase), from the systems`s conventional steady-state sinusoidal phase and group-delay responses.
| Click to Browse |
| Keele, Jr., D. B. (Don); 1991; Measurement of Polarity in Band-Limited Systems [PDF]; Audio Magazine, Hachette Magazines, Inc., New York, NY ; Techron, Div. Crown International, Inc., Elkhart, IN ; DBK Associates, Inc., Elkhart, IN; Paper 3168; Available from: https://aes2.org/publications/elibrary-page/?id=5548 |